130 XgOS User’s Guide • September 2014
1. Configure the Ethernet port mode:
2. Add vNICs to the hosts:
3. On the hosts, configure IP address information.
Example 4: Port Trunk Mode, VLAN-Unaware Host and
HA vNICs
In this example, the following environment applies:
■ HA vNIC pairs are configured on the Oracle Fabric Interconnects.
■ The servers are using the Linux or Windows operating system.
■ ESX Server uses its own NIC teaming to achieve an HA interconnect.
■ The hosts are not VLAN aware.
Consider the example in the following figure.
set ethernet-port 15/1 -mode=trunk -access-vlan=1
add vnic vn1.s1 15/1 -mode=access -access-vlan=20
add vnic vn1.s2 15/1 -mode=access -access-vlan=10