AMD LE-363 User's Guia do Utilizador Página 303

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 436
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 302
Chapter 16 Monitoring XgOS 277
Note If you need to integrate/compile the Xsigo MIBs, you can get them from the
Oracle Xsigo Support Portal (http://www.xsigo.com/support).
Hardware Monitoring
The following chassis information can be monitored:
Chassis operational state
I/O module type and operational state
I/O port operational state
Fan operational state
Power Supply (PSU) operational state
Chassis Status
The Oracle Fabric Interconnect chassis status should be in the up state, unless you
have a failure in the system, such as a fan failure.
With symbolic object name:
With numeric OID:
Issue a show alarm command should this value be in a state such as
“partialFailure(28).”
I/O Module Status
Every I/O module should be in the up state, unless the Oracle Fabric Interconnect
has just been rebooted and the I/O modules are still in the process of
loading/booting the operating code.
$ snmpwalk -c public -v2c -mALL 192.168.10.100 xsigoChassisOperState
XSIGO-IODIRECTOR-ENTITY-MIB::xsigoChassisOperState.0 = INTEGER: up(2)
$ snmpwalk -c public -v2c -mALL 192.168.10.100 -On xsigoChassisOperState
.1.3.6.1.4.1.24440.3.1.1.1.14.0 = INTEGER: up(2)
Vista de página 302
1 2 ... 298 299 300 301 302 303 304 305 306 307 308 ... 435 436

Comentários a estes Manuais

Sem comentários